minimal.xml Set Loweheiser desired states EFI Index Desired Engine/EFI State (0: Power Off, 1:Running) Desired Governor State (0:manual throttle, 1:Governed throttle) Manual throttle level, 0% - 100% Electronic Start up (0:Off, 1:On) Empty Empty Composite EFI and Governor data from Loweheiser equipment. This message is created by the EFI unit based on its own data and data received from a governor attached to that EFI unit. Generator Battery voltage. Generator Battery current. Current being produced by generator. Load current being consumed by the UAV (sum of curr_gen and curr_batt) Generator fuel remaining in litres. Throttle Output. Seconds this generator has run since it was rebooted. Seconds until this generator requires maintenance. A negative value indicates maintenance is past due. The Temperature of the rectifier. The temperature of the mechanical motor, fuel cell core or generator. EFI Supply Voltage. Motor RPM. Injector pulse-width in milliseconds. Fuel flow rate in litres/hour. Fuel consumed. Atmospheric pressure. Manifold Air Temperature. Cylinder Head Temperature. Throttle Position. Exhaust gas temperature. EFI index. Generator status. EFI status.